The main function

The Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 ° C to 350 ° C, while The cold block covers The range of 15 ° C to 110 ° c. Each block is controlled by a precision Hart Scientific temperature controller. These aren 't some off - The - shelf controllers we glued into a box. These are Hart Scientific controllers from The leading temperature company in The world.

Each temperature block includes two Wells with removable inserts, You can calibrate four the probes at once, or You can calibrate two the probes at the same time with an external reference (like Hart "s Model 1521 LLK Thermometer), or You can use the two temperature Wells to get quick" zero "and" span "references for transmitter calibrations.

Need portability and durability?The 9009 is housed in a tough Pelican ™ case belong to both airtight and watertight. It 's a small package weighing only 10 pounds, yet It fits everything you need, o a power cord and four extra inserts. The inserts are available to accommodate sensors of any size from 1/16 "to 7/16" (1.6 mm) (11.1 mm). This rugged system can go anywhere.

Of course the 9009 also delivers the performance you expect from a Hart Scientific temperature source. The cold block is calibrated to within + / - 0.2 ° C with stability Of + / - 0.05 ° c. the hot block 's display is accurate to + / - 0.6 ° C with stability Of + / - 0.05 ° c. a. NIST - traceable calibration is included for each Of the two test blocks.

For use with automated systems, the 9009 comes with an RS - 232 connection, which allows you to control and monitor temperatures from your PC. For completely automated calibrations, Hart's MET/TEMP II software also integrates with the 9009.

Two blocks in one unit, a total range of 15 ° C to 350 ° C, portability, durability, versatility, performance, automation, Hart Scientific delivers it all.

Produc爱游戏平台是正规的吗ts overview: Fluke correction 9009 portable catamaran dry type furnace

Double your the productivity or cut your calibration time in half

  • Temperatures from 15 ° C to 350 ° C in one unit
  • Two Wells in each block for simultaneous comparison calibrations
  • Rugged, lightweight, water - resistant enclosure

You 've had have the for it and now we' re making it for You. Hart "s new Model 9009 Industrial Dual - Block Calibrator lets You calibrate the at hot and cold temperatures at the same time. The Double your the productivity or cut your calibration time in half - either way You look at it, your in - field temperature calibrations just got easier.

Spec爱游戏平台是正规的吗ification: 9009 portable Fluke correction catamaran dry type furnace

The General Specifications
Hot block Cold block
The Range 50 ° C to 350 ° C (122 ° F to 662 ° F) 15 ° C to 110 ° C (5 ° F to 230 ° F)
(-- 8 ° C [18 ° F] with hot block at 350 ° C / 662 ° F)
Accuracy + / - 0.6 ° C + / - 0.2 ° C
Stability + / - 0.05 ° C
Well - to - Well uniformity + / - 0.1 ° C
The Display resolution 0.1 °
Heating times 30 minutes from 25 ° C to 350 ° C 15 minutes from 25 ° C to 110 ° C
Cooling times 40 minutes from 350 ° C to 100 ° C 16 minutes from 25 ° C to 15 ° C
Stabilization times Eight minutes
Well the depth 4 in (102 mm)
Removable inserts Two 6.4 mm (1/4) in the and Two 4.8 mm (3/16 in) inserts included;See ordering information for other available inserts
Computer interface The RS - 232 included
The Power 115 V AC (+ / - 10%), 3 A, an or
230 V AC (+ / - 10%), 2 A, specify, 50/60 Hz, 280 W
The Size (H x W x D) 178 x 267 x 248 mm (9.75 in 7 x 10.5 x)
Weight 4.5 kg (1 lb)
NIST - traceable calibration Data at 50 ° C to 100 ° C to 150 ° C to 200 ° C to 250 ° C to 300 ° C, and 350 ° C Data at 8 ° C, 0 ° C, 25 ° C, 50 ° C and 75 ° C and 100 ° C, and 110 ° C

Mode爱游戏平台是正规的吗l: Fluke correction 9009 portable catamaran dry type furnace

爱游戏平台是正规的吗Fluke 9009 - B - 156
爱游戏平台是正规的吗Fluke Calibration 9009 Dual - Well Dry - Well, Dual Block (Black), 110 v 50/60 hz
buy

Manual + 爱游戏平台是正规的吗resource: Fluke correction 9009 portable catamaran dry type furnace