爱游戏平台是正规的吗Fluke Calibration 1524 Handheld Thermometer Readout
The main function
In order to ensure compliance, to gain excellent yield, excellent energy saving effect and stable and consistent results, you need accurate measurement.In 1524 adopted the only high-end instrument to use the power of backward technology, eliminates the thermoelectric emfs (EMF), thus can realize accurate temperature measurement.According to the design specification, it can be - DHS 10 to 60 C DHS C environment normal work.Special precision resistance and high stability of the reference voltage source can make 1524 almost not affected by the external environment temperature.
Like al爱游戏平台是正规的吗l other handheld tools Fluke, 1524 reference thermometer in extreme temperatures, and the vibration of the harsh conditions after a rigorous testing.
Therefore, the user can take it to any where it is needed.Optional magnetic suspension device allows the user to hang the thermometer, not only easy to see, still can make his hands to focus on work.
The INFO - CON connectors to ensure the correct temperature conversion
INFO - CON joint built-in memory chips contain information used to connect the probe calibration.Simply insert the probe, and the calibration information can be uploaded to the reader, to ensure that the correct temperature conversion, so as to realize the measurement of accurate without interference.
For safety or the traceability system calibration, user can set the password to the probe locked to a specific channel and reader.User can insert the thermocouple with a mini plug optional general thermocouple adapter, convenient measurement.Each thermocouple adapter or standard joint through internal precision thermistor support thermocouple cold junction compensation (RJC).
In the laboratory or field monitoring trends
In 1524 128 x64 LCD backlit thermometer see trends in graphics.In addition, just touch of a button can change the resolution of the graphics.Now, you can easily view during temperature stabilized (without statistics or long time delay), and monitor process over a period of time to verify whether it is right to operate.
According to the need to record up to 25 pairs of readings and related statistical data, convenient retrieval.The user can view the data from your screen, also can through the RS - 232 interface to upload to PC with 9940 software (free attached) to see.In a period of time to monitor and record more data, please use PC and optional LogWareII software.
For users like to use the USB connector, also can use the provided by RS - 232 / USB adapter.Using three AA batteries, battery can last for at least 20 hours, also can use dc power adapter in order to realize the measurement for a longer time.In order to achieve a longer battery life or more convenience, the user can enable or disable the power saving function.
Two models for choice
1524 reference thermometer is a multifunctional single channel thermometer, let users through a tool can measure three types of sensors, drawing, and records.Due to the support of PRT/RTD, thermocouple and thermistor, so users can correct probe flexibility to choose suitable for their work.
The new 1524 reference meter allows users to use double the work completed in half the time.Two channels, three kinds of sensor types and high speed measurement allows the user to work more efficiently, makes 1524 users a kind of essential reference thermometer.It has all the features of 1523, at the same time, it is also a data recorder.Real time clock and the date and time can record 15000 times of measurement means that this kit provides everything you need for a user.Record frequency can be three times per second, one hour at a time, or between the two options.When necessary, can also download the data to PC for analysis.
application
1524 thermometer USES is very wide, and some application examples including calibration, loop check, workshop start test, troubleshooting, maintenance, repair and so on.Using it, the user can in the bathroom, dry postures temperature calibration instrument, the thermometer casing, clean room, engine, heat exchanger, furnace, freezer, or any other places need calibration, inspection or maintenance convenient temperature measurement.
Produc爱游戏平台是正规的吗ts overview: Fluke Calibration 1524 Handheld Thermometer Readout
Use a tool to measure, mapping and record three types of sensors
爱游戏平台是正规的吗Fluke subsidiary Hart Scientific Division launched 1524 reference thermometer can measure, drawing and document PRT, thermocouple and thermistor.The thermometer readings have excellent precision, wide range, recording and trend of drawing function, all of this are completed by a portable hand-held tool.
1524 allows you to easily cope with field application, laboratory measurement and data records.In addition, with the 1524 model of dual channel measurement functions, users can also use a double work completed in half the time.
Three types of sensors
- PRT: - 200 ° C to 1000 ° C
- Thermocouple: - 200 ° C to 2315 ° C
- Precision thermistor: - 50 ° C to 150 ° C
precision
- PRT: up to + / - 0.011 ° C
- Thermocouple: + / - 0.24 ° C, suitable for J, K, L and M type
- Precision thermistor: + / - 0.002 ° C
Fast mode
- PRT: sampling 0.45 seconds at a time
- Thermocouple: sampling 0.3 seconds at a time
- Precision thermistor: sampling 0.3 seconds at a time
Two kinds of models
- 1523: single channel standard model;Can record article 25 readings and statistical data of storage
- 1524: dual channel;Measurement of memory can record 15000 times;Mark the real time clock is used to display the date and time
Graphical display
- 128 x64 LCD backlit graphical display
- Real-time graphics and trends
- Synchronous dual channel readings
Spec爱游戏平台是正规的吗ification: Fluke Calibration 1524 Handheld Thermometer Readout
Technical indicators | |||||||
Input channel |
|
||||||
The log |
|
||||||
Sampling interval (standard) |
|
||||||
Sampling interval (fast mode) |
|
||||||
The sensor type |
|
||||||
Thermocouple type |
|
||||||
Operating temperature |
|
||||||
The power supply requirements |
|
||||||
size |
|
||||||
The weight of the |
|
||||||
The precision of optimal environmental conditions |
|
||||||
Millivolt range and accuracy |
|
||||||
Resistance range and accuracy |
|
||||||
Temperature coefficient, voltage (- 10 ° C to 13 ° C and + 33 ° to 60 ° C) C |
|
||||||
The temperature coefficient of resistance (-- 10 ° C to 13 ° C, 33 ° to 60 ° C + C) |
|
||||||
The exciting current and resistance |
|
Equivalent temperature thermocouple accuracy (reader) only | |||||||
Type B |
|
||||||
C |
|
||||||
E |
|
||||||
J type |
|
||||||
K type |
|
||||||
L |
|
||||||
M type |
|
||||||
N |
|
||||||
R |
|
||||||
"S" |
|
||||||
T |
|
||||||
U |
|
||||||
Note 1: |
|
The precision of 1523/24 using the selected probe (plus or minus ° C) | |||||||||
- 200 ° C |
|
||||||||
0 ° c. |
|
||||||||
100 ° c. |
|
||||||||
300 ° c. |
|
||||||||
420 ° c. |
|
||||||||
Including reader accuracy, sensor calibration and sensor drift |
|
PRT equivalent temperature accuracy (reader) only | |||
- 100 ° C |
|
||
0 ° c. |
|
||
100 ° c. |
|
||
200 ° c. |
|
||
400 ° c. |
|
||
600 ° c. |
|
Thermistor equivalent temperature accuracy (reader) only | |||
0 ° c. |
|
||
25 ° c. |
|
||
50 ° c. |
|
||
75 ° c. |
|
||
100 ° c. |
|
Mode爱游戏平台是正规的吗l: Fluke Calibration 1524 Handheld Thermometer Readout
1524 Bundled with 5628 PRT, Universal TC INFO - CON Connector, TPAK, and Case
The molbloc Mass Flow Element
1524 Bundled with 5627 a PRT, Universal TC INFO - CON Connector, TPAK, and Case
Includes:
- 5627 a PRT
- The Universal TC INFO - CON Connector
- TPAK
- Case
1524 Bundled with 5615 PRT
Includes:
- 5616 PRT
- The Universal TC INFO - CON Connector
- TPAK
- Case